UV Systems
UV systems will protect you from living organisms in your water such as bacteria and cysts. Ultraviolet (UV) water purification systems are trusted by thousands of people worldwide for use in homes, cottages, and in many industrial and commercial applications. UV systems come in a variety of sizes and can be used to purify the water for a single faucet or for an entire home or larger building. UV systems are superior to chemical water disinfection because they don't add any harmful chemicals to the water, or to the environment.
MICRO – BIOLOGICAL PROBLEM IN VARIOUS INDUSTRIES:
Pharmaceuticals Industry : # Bacterial count in process water.
# Bacterial growth in sand filter, Carbon filter, D.M. Plant.
# Decreased shelf life of the R.O. Membrane, Resin & Filter beds etc.
Bottling Industry : # Decreased shelf life of the end mineral water, Soft Drink, product.
Dairy Canneries : # Contamination of bottles.
# Bacterial growth in Sand filter, Carbon filter, D.M.Plant.
Food & Beverage Industry : # Decreased shelf life of the end product.
Fish Hatcheries : # Whirling disease.
# Increased fish mortality.
Paint Industry : # Decreased shelf life of the water based paints.
Poultry Industry : # Increased bird mortality.
Specification:
- Ultra violet radiation is natural source of purification.
- Ultra violet radiation band of invisible light in the electromagnetic spectrum, in the range of 200 – 400 nm wavelengths.
- The U.V. wavelength of 253.7 nm possesses the greatest germicidal effectiveness, which Penetrate the microbial cell membrane to destroy the DNA molecule thus preventing cell Replication.
- U.V. is used to provide Bacterial Disinfection in water. It does not change the Physical or Chemical Characteristics in water. U.V. provides disinfection On Contact. It does not have any residual properties left in treated water.
- Special High Germicidal Lamps produce high U.V. output in 254 nm range.
- There are no know micro organisms resistant to U,V,
- U.V. water purification is preferred the world over because it is the simplest & most practical means of destroying micro organisms in water.
CONVENTIONAL METHODS OF WATER TREATING |
|
CHLORINE |
OZONE |
ULTRA VIOLET |
Capital cost |
Lowest |
High |
Low |
Ease of installation |
Good |
Poor |
Excellent |
Ease of Maintenance |
Good |
Poor |
Excellent |
Cost of Maintenance |
Medium |
High |
Lowest |
Operating Cost |
Low |
High |
Low |
Frequency Of Maintenance |
Frequent |
Continuous |
V. Infrequent |
Control System |
Poor |
Good |
Excellent |
Virucidal Effect |
Good |
Poor |
Good |
Toxic Chemical |
Yes |
Yes |
No |
Residual Effect Problem with |
Yes |
Yes |
No |
Hazards |
High |
Yes |
Low to none |
Contact Time |
30 - 60 minutes |
High |
1 – 5seconds |
Disinfection Performance |
Leaves some pathogens |
Kills all microbes |
Kills all microbes |
Effect on Water |
Organochlorine compounds, Taste & pH changes |
Unknown |
None |
The Ultra violet dose required for destruction is about the same for each virus, while higher dose of chlorine & ozone needed. |
MIROBIAL STANDARDS FOR DRINKING WATER |
Test |
W.H.O. |
U.S.P.H.A. |
SWE Standard |
Total Bacterial Count |
Test not specified |
500 organisms/ml. |
Les than 500 organisms/ml. |
Coli form |
95% of sample should not coli forms & maximum 10 coliforms/100ml. |
95% of sample should not contain coli form |
NIL ( Coli forms ) |
E-Coli |
No E.Coli in 100ml. |
No E.Coli in 100ml. |
NIL ( E. Coli ) |
SR.NO |
FLOW RATE /HRS |
MODEL NO |
INLET & OUTLET |
NO.UV LAMP &
Q .JACKET |
POWER( WATTS) |
1. |
|
SWE - 1 |
½” THRD |
1 |
8 |
2. |
|
SWE - 2 |
½” BSP |
1 |
16 |
3. |
|
SWE – 2X2 |
¾” BSP |
2 |
16 |
4. |
|
SWE 4X2 |
¾” BSP |
2 |
32 |
5. |
|
SWE 8 |
¾” BSP |
1 |
39 |
6. |
|
SWE 16 |
1” BSP/25 NB |
2 |
80 |
7. |
|
SWE 50 |
1.5” BSP /40 NB |
3 |
120 |
8. |
|
SWE -32 |
1.5” BSP / 40 NB |
4 |
160 |
9. |
|
SWE – 100 |
2”BSP/50 NB |
6 |
240 |
10. |
|
SWE – 150 |
2”BSP/50 NB |
8 |
320 |
11. |
|
SWE – 250 |
( 2 Chamber ) 50NB |
12 |
480 |
12. |
|
SWE - 350 |
( 2 Chamber ) 50NB |
16 |
640 |
13 |
|
SWE – 450 |
( 3 Chamber ) 80NB |
18 |
720 |
14 |
|
SWE – 650 |
( 4 Chamber ) 80NB |
24 |
960 |
Main Feature:
- U.V. Chamber S.S. 316 electropolished purification chamber for life time corrosion free service.
- High intensity U.V. lamp of continuously use. ( Imported )
- Quick lamp change in less than a minute without shut down of water pressure or drainage of chamber.
- Lamp Monitor indicates functioning of the U.V lamp
- Quartz jackets silica used for its proven capability of 99% transmitting maximum Ultra Violet rays for peak Ultra Violet dosage 30,000 uW sec / cm2 .
- Wiper Assembly facilities periodic cleaning of quartz glass to ensure peak efficiency without interruption of purifier operation
- Working pressure maximum 3.5 kg/ cm2 or gravity.
- Continuously 24 hours use. Operating expenses of less than one paisa per 10 liters of purified water.
- Removable Flange Heads for easy and complete disassembly without use of special tools.
OPTIONAL ACCESSORIES :
- Time Elapse Meter for identification of U.V lamp life utilized
- Optional Prefilter for cloudy water or filtration systems .
- Ultraviolet Monitor to sense and indicate the level of germicidal U.V dosage 30,000 uW sec / cm2
QUALITY CONTROL:
Every U.V lamp & Quartz jacket Silica individually checked and each completed
System tested and run before dispatch
Check Stainless steel & silicon material i.e. Gasket, ‘o’ Ring with Validation certificates.
Our comprehensive after sales service includes a full range of spares and professional technical backup, with an optional Annual Maintenance Contract in all over India.
|